APLISENS SA Warszawa, Poland
emergency power suppliesflow meters, fuel oillevelpressure, vacuumtransducers, transmitters temperature and pressurevalve, pressure controlvalve, pressure reducing
APC-2000 ALWAPCE-2000PD and APCE-2000PZAPR-2000 ALWAPR-2000G ALAPRE-2000GAPRE-2000PD and APRE-2000PZAPRE-2200ASAS-dPCS-25/I; CS-25/U; CS-25/RSMS-100K PCE-28PCE-28PPRE-28SG.Profibus PASGE-25 Smart and SGE-25S SmartSGE-25 and SGE-16SGE-25S and SGE-25CVM-3 and VM-5ZL-24-01ZL-24-08ZS-30EEx1ZS-31EEx1ZSP-41
Presentation: www.aplisens.equip4ship.com
Address: Poland, Warszawa, 03-192 Morelowa 7
Contact person: e-mail, website
Phone: +8140777
Fax: +8140778
Intrinsically safe network power supply and separator
Send enquiry
230 V AC power supply
Full galvanic separation of circuits (IN-OUT, IN-SUPPLY, OUT-SUPPLY)
Accuracy 0.1%
Casing can be fitted on a standard TS35 rail
Full galvanic separation of circuits (IN-OUT, IN-SUPPLY, OUT-SUPPLY)
Accuracy 0.1%
Casing can be fitted on a standard TS35 rail
ZS-31EEx1
Intrinsically safe power supply and separator
Send enquiry
24 V DC power supply
Full galvanic separation of circuits (IN-OUT, IN-SUPPLY, OUT-SUPPLY)
Accuracy 0.1%
Casing can be fitted on a standard TS35 rail
Full galvanic separation of circuits (IN-OUT, IN-SUPPLY, OUT-SUPPLY)
Accuracy 0.1%
Casing can be fitted on a standard TS35 rail
ZS-30EEx1
Power supply/separator/signal converter
Send enquiry
Full galvanic separation of circuits (IN-OUT, IN-SUP, OUT-SUP)
Ability to select input and output signals
Ability to use input line to power a two-wire transmitter
Casing can be fitted on a standard TS35 rail
Ability to select input and output signals
Ability to use input line to power a two-wire transmitter
Casing can be fitted on a standard TS35 rail
ZSP-41
Power supply
Send enquiry
Maximum output current 100 mA or 2 x 50 mA
Indication of presence of output voltage
Permanently resistant to short circuits and excess voltage
Casing can be fitted on a standard TS35 rail
Indication of presence of output voltage
Permanently resistant to short circuits and excess voltage
Casing can be fitted on a standard TS35 rail
ZL-24-01
Power supply
Send enquiry
Maximum output current 800 mA
High energy efficiency
Indication of the presence of output voltage
Permanently resistant to short circuiting and excess voltage
Overvoltage protection
Casing can be fitted on a standard TS35 rail
High energy efficiency
Indication of the presence of output voltage
Permanently resistant to short circuiting and excess voltage
Overvoltage protection
Casing can be fitted on a standard TS35 rail
ZL-24-08