APLISENS SA Warszawa, Poland
emergency power suppliesflow meters, fuel oillevelpressure, vacuumtransducers, transmitters temperature and pressurevalve, pressure controlvalve, pressure reducing
APC-2000 ALWAPCE-2000PD and APCE-2000PZAPR-2000 ALWAPR-2000G ALAPRE-2000GAPRE-2000PD and APRE-2000PZAPRE-2200ASAS-dPCS-25/I; CS-25/U; CS-25/RSMS-100K PCE-28PCE-28PPRE-28SG.Profibus PASGE-25 Smart and SGE-25S SmartSGE-25 and SGE-16SGE-25S and SGE-25CVM-3 and VM-5ZL-24-01ZL-24-08ZS-30EEx1ZS-31EEx1ZSP-41
Presentation: www.aplisens.equip4ship.com
Address: Poland, Warszawa, 03-192 Morelowa 7
Contact person: e-mail, website
Phone: +8140777
Fax: +8140778
Differential pressure transmitter
Send enquiry
Measuring range: min. 0 ... 20 mbar, max. 0... 16 bar
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,25%
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,25%
PRE-28
Differential pressure transmitter
Send enquiry
Measuring range: min. 0 ... 1 bar, max. 0... 25 bar
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,4%
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,4%
AS-dP
Smart differential pressure transmitter
Send enquiry
Measuring range: min. 0...4 mbar, max. 0...16 bar
Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA
Accuracy: 0,075%
Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA
Accuracy: 0,075%
APR-2000 ALW
Smart differential pressure transmitter
Send enquiry
Measuring range: min. 0 ... 4 mbar, max. 0... 16 bar
Output signal: 4...20 mA + protocol HART
Accuracy: 0,1%
Output signal: 4...20 mA + protocol HART
Accuracy: 0,1%
APRE-2000PD and APRE-2000PZ
Smart differential pressure transmitter for low ranges
Send enquiry
Programmable zero shift and damping ratio
Selectable linear or radical conversion characteristic
Output signal: 4...20 mA + HART
Accuracy: 0,1% (1%)
Selectable linear or radical conversion characteristic
Output signal: 4...20 mA + HART
Accuracy: 0,1% (1%)
APR-2000G AL
Smart pressure transmitter for low ranges
Send enquiry
Measuring range: min. 0 ... 0,2 mbar, max. 0... 100 mbar
Output signal: 4...20 mA + HART
Accuracy: 0,1% (1%)
Process connection: to fi 6x1 pipe, mounted with a valve manifold
Output signal: 4...20 mA + HART
Accuracy: 0,1% (1%)
Process connection: to fi 6x1 pipe, mounted with a valve manifold
APRE-2000G
Level measurement
Send enquiry
Smart or analog differential pressure transmitters with diaphragm seals for level measurement
Smart differential pressure transmitter with remote diaphragm seals
Send enquiry
Measuring range: min. 0 ... 0,1mH2O, max. 0... 16 bar
Output signal: 4...20 mA + protocol HART; Profibus PA
Accuracy: 0,1%
Output signal: 4...20 mA + protocol HART; Profibus PA
Accuracy: 0,1%
APRE-2200
Smart pressure transmitter
Send enquiry
Measuring range: min. 0...1 mbar; max. 0... 400 bar
Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA
Accuracy: 0,075%
Process connection: M20 x 1,5; G 1/2"; G 1/2";
G 1" (flush diaphragm); M30 x 2;
M20 x 1,5
Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA
Accuracy: 0,075%
Process connection: M20 x 1,5; G 1/2"; G 1/2";
G 1" (flush diaphragm); M30 x 2;
M20 x 1,5
APC-2000 ALW
Smart pressure transmitter
Send enquiry
Measuring range: min. 0...1 mbar; max. 0...400 bar
Output signal: 4...20 mA + protocol HART
Accuracy: 0,1% (0,075%)
Process connection: M20 x 1,5; G 1/2"; G 1/2";
G 1" (flush diaphragm); M30 x 2;
M20 x 1,5;
Diaphragm seals;
Output signal: 4...20 mA + protocol HART
Accuracy: 0,1% (0,075%)
Process connection: M20 x 1,5; G 1/2"; G 1/2";
G 1" (flush diaphragm); M30 x 2;
M20 x 1,5;
Diaphragm seals;
APCE-2000PD and APCE-2000PZ
Pressure transmitter
Send enquiry
Measuring range: min. 0...10 mbar; max. 0...1000 bar
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,2% (0,16%)
Process connection: M20 x 1,5; G 1"; G 1/2";
G 1" (flush diaphragm); M30 x 2;
M20 x 1,5;
Diaphragm seals
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,2% (0,16%)
Process connection: M20 x 1,5; G 1"; G 1/2";
G 1" (flush diaphragm); M30 x 2;
M20 x 1,5;
Diaphragm seals
PCE-28
Pressure transmitter
Send enquiry
Measuring range: min. 0 ... 0,1 bar; max. 0... 60 bar
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,4%
Process connection: M20 x1,5; G 1/2"; R 1/2"
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,4%
Process connection: M20 x1,5; G 1/2"; R 1/2"
AS